| MRC |
Requirement Statement |
Characteristics |
| AGAV |
END ITEM IDENTIFICATION |
GENERATOR, 30KW, DIESEL, MILITARY STANDARD FAMILY SUPPORT EQUIPMENT, B-52 AIRCRAFT SUPPORT EQUIPMENT, H-3 HELICOPTER TRUCK, FIRE/CRASH P2 GENERATOR, 15KW, DIESEL, MILITARY STANDARD FAMILY HELICOPTER, MH-53E CHILLED WATER A/C SYSTEMS HELICOPTER, ADV |
| AASB |
FASTENER LENGTH |
1.438 INCHES MINIMUM AND 1.500 INCHES MAXIMUM |
| CQFM |
HARDNESS RATING |
25.0 ROCKWELL C MINIMUM OVERALL AND 34.0 ROCKWELL C MAXIMUM OVERALL |
| AASU |
HEAD HEIGHT |
0.195 INCHES MINIMUM AND 0.211 INCHES MAXIMUM |
| AASK |
HEAD STYLE |
HEXAGON |
| MDCL |
MATERIAL DOCUMENT AND CLASSIFICATION |
SAE J429 ASSN STD ALL MATERIAL RESPONSES OVERALL |
| MATT |
MATERIAL |
STEEL COMP 1013 OVERALL OR STEEL COMP 1015 OVERALL OR STEEL COMP 1016 OVERALL OR STEEL COMP 1017 OVERALL OR STEEL COMP 1018 OVERALL OR STEEL COMP 1019 OVERALL OR STEEL COMP 1020 OVERALL OR STEEL COMP 1021 OVERALL OR STEEL COMP 1022 OVERALL OR STEEL COMP 1 |
| CQBC |
MINIMUM TENSILE STRENGTH |
120000 POUNDS PER SQUARE INCH |
| AHYM |
NOMINAL THREAD DIAMETER |
0.312 INCHES |
| ZZZT |
NONDEFINITIVE SPEC/STD DATA |
2 TYPE AND 10P STYLE AND 5 GRADE |
| THSD |
THREAD SERIES DESIGNATOR |
UNF |
| AATB |
WIDTH BETWEEN FLATS |
0.489 INCHES MINIMUM AND 0.500 INCHES MAXIMUM |
| STDC |
SURFACE TREATMENT DOCUMENT AND CLASSIFICATION |
QQ-P-416,TY 2 CL 2 FED SPEC SINGLE TREATMENT RESPONSE OVERALL |
| SFTT |
SURFACE TREATMENT |
CADMIUM OVERALL AND CHROMATE OVERALL |
| AAJD |
THREAD CLASS |
2A |
| AAJF |
THREAD DIRECTION |
RIGHT-HAND |
| AASA |
THREAD LENGTH |
0.875 INCHES MINIMUM AND 1.062 INCHES MAXIMUM |
| CMLP |
THREAD QUANTITY PER INCH |
24 |