| MRC |
Requirement Statement |
Characteristics |
| AKNU |
DEFLECTION AT STATIC LOAD RATING |
2.00 INCHES MAXIMUM |
| HGTH |
HEIGHT |
5.00 INCHES MINIMUM AND 5.50 INCHES MAXIMUM |
| MATT |
MATERIAL |
ALUMINUM ALLOY MOUNTING PLATE |
| MATT |
MATERIAL |
STEEL CORROSION RESISTING DAMPER |
| ABRY |
LENGTH |
14.47 INCHES MINIMUM AND 14.53 INCHES MAXIMUM |
| CXCY |
PART NAME ASSIGNED BY CONTROLLING AGENCY |
WIRE ROPE ISOLATOR |
| FEAT |
SPECIAL FEATURES |
ITEM HAS 8 MOUNTING HOLES, 4 ON THE TOP AND 4 ON THE BOTTOM MOUNTING PLATE SPACE FROM 1ST TO 2ND HOLE IS 3.00IN, SPACE FROM 1ST TO 3RD HOLE IS 7.50IN AND SPACE FROM THE 1ST TO THE LAST HOLE IS 10.5IN 8 LOOPS MOUNTING HOLE THREAD IS M12 X 1.75 |
| ABGL |
WIDTH |
5.50 INCHES NOMINAL |
| AKMZ |
STATIC LOAD RATING |
2760.0 POUNDS MAXIMUM |
| STYL |
STYLE DESIGNATOR |
RECTANGULAR W/WIRE ROPE |